PRICING FOR UPLC AND MASS SPECTROMETRY SERVICES

 

PRICING (VALID AUGUST 2017 TO AUGUST 2018)

SERVICE

INTERNAL KUMC PRICING

EXTERNAL ACADEMIC PRICING

INSTRUMENT  ONLY ACCESS

UPLC & UPLC-MS SELF-SERVICE

$15 per injection

$30 per injection

UPLC & UPLC-MS FULL-SERVICE

$18 per injection

$36 per injection

CUSTOM ASSAY DEVELOPMENT (TWO-DAY MINIMUM BOOKING)

SERVICE LEVEL ONE

$480 for first two days;
$240 per day thereafter.

$960 for first two days;
$480 per day thereafter.

SERVICE LEVEL TWO

$240 for first day;
$120 per day thereafter.

$480 for first day;
$240 per day thereafter.

SERVICE LEVEL THREE

$160 per day.

$320 per day.

BILE ACID STANDARDIZED PANEL ASSAY2

SERVICE LEVEL ONE

$28 per sample extraction & injection.
$16 for duplicate injection of extract.

$44 per sample extraction & injection.
$22 for duplicate injection of extract.

SERVICE LEVEL TWO

$26 per sample extraction & injection.
$14 for duplicate injection of extract.

$42 per sample extraction & injection.
$21 for duplicate injection of extract.

SERVICE LEVEL THREE

$24 per injection.
$12 for duplicate injection of extract.

$38 per injection.
$19 for duplicate injection of extract.

 APAP METABOLITE ASSAY2

 SERVICE LEVEL ONE

$26 per sample.
$13 for duplicate injection of extract

$40 per sample extraction & injection.
$20 for duplicate injection of extract.

 SERVICE LEVEL TWO

$24 per sample.
$12 for duplicate injection of extract

$38 per sample extraction & injection.
$19 for duplicate injection of extract.

 SERVICE LEVEL THREE

$21 per injection.
$11 for duplicate injection of extract.

$36 per injection.
$18 for duplicate injection of extract

  AMINO ACID ASSAY2

 SERVICE LEVEL ONE

 T.B.D.

 T.B.D.

 SERVICE LEVEL TWO

 T.B.D.

 T.B.D.

 SERVICE LEVEL THREE

 T.B.D.

 T.B.D.

EDUCATIONAL SERVICES

FORMAL USER TRAINING

$100 per person, per instrument.3

THE SMALL PRINT 

1Sample extraction includes tissue homogenization, analyte extraction and any polishing steps (i.e. SPE)
2Level two service: Client provides the labor for sample extraction. ACL provides the equipment and consumables.
3Training fee waived if required to begin a self-service project consisting of 20 or more injections.  

 

IMPORTANT NOTICES:

  1. 2017 rates will apply from August 1, 2017

  2. Users wishing to use the ACL's Lab Logic Beta Ram 4 Scintillation Counter must have obtained radiation safety certification from KUMC's EHS department before use.

  3. Investigators should build in a 25% price increase each year when building his/her Grant application budget.

  4. Additional charges will be applied in the following instances:

    • Excessive use of consumables (solvents, plastic and single-use specialized glassware) during sample preparation.

      a.  U/HPLC mobile phases should be considered to be perishable and clients need to take this into consideration when preparing them.

              --    These mixtures are subject to out-gasing of volitile components or microbial contamination or both.
              --    
      Mobile phase mixtures are to prepared in volumes rationally related to their immediate use.

              --     Preparation of excessive amounts of these compounds will result in additional charges being levied.
      b.  LC-MS instruments utilize single-use auto-injector vials whose precise dimensions command a premium price-tag.

             --      If you use autosampler vials for sample preparation purposes, you will be charged extra.

             --      For those projects that require low volume or glass-only manipulations or both: use cheaper mass produced glass tubes and vials vessels.

      c.   Breakage of equipment due to inappropriate handling.
            --      
      Mobile phases containing dissolved components that ~must~ be filtered through the 0.22 µm GHP or Nylon filters supplied to clients by the ACL. NO exceptions!  The full price of replacing fouled filters and torn high-pressure seals will be chared to any researcher who violates the mandatory filtration rule!
            --      
      The ACL's mass spectrometers are sensitive to detergents, thus the only ACL-owned and maintained glassware is permitted. The ACL provides all necessary glassware and washes it for you. Therefore clients who violate this rule will be charged the full cost of decontaminating the LC-MS!